e-Shop

EPIC® K 4/2

Combination insert Power and Control

The combined insert is suitable for power and control and can be used, for example, in the area of recoverable energy and control systems.

Combination insert Power and Control

Supplementary automation components from Lapp Mechanical and plant engineering Wind Energy Temperature-resistant

cRUus

Article number Article description Contact type Number of operating contacts Pieces / PU Base Unit Price (base price)
EPIC® K 4/2 screw termination
44424043
EPIC® K 4/2 SS male 4 + 2 + PE 10
44424044
EPIC® K 4/2 BS female 4 + 2 + PE 10
Available from stock
Available soon
Not available

Benefits

  • Power and control in one connector insert
  • Best in combination with ÖLFLEX® SERVO

Application range

  • Mechanical engineering
  • Control engineering
  • Renewable energy

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000438
  • ETIM 5.0 Class-Description: Contact insert for industrial connectors

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000438
  • ETIM 6.0 Class-Description: Contact insert for industrial connectors

Rated voltage (V)

  • 830 V Power
  • 400 V Control

Rated impulse voltage

  • 8 kV

Rated current (A)

  • 80 A Power
  • 16 A Control

Pollution degree

  • 3

Flammability

  • UL94 V-0

Contact resistance

  • < 5 mOhm

Number of contacts

  • 4 + 2 + PE

Termination methods

  • Screw termination: 1.5 - 16.0 mm² (power contact)
  • Screw termination: 0.5 - 2.5 mm² (control contact)

Stripping length (mm)

  • 16 mm (Power)
  • 6 mm (Control)

Material

  • PC, polycarbonate

Cycle of mechanical operation

  • 500

Certifications

  • UL-tested:
    UL File Number: E75770

Temperature range

  • -40°C to +125°C

  • PE connection with a 16mm² wire only with the recommended ring lug 44424029
  • The inserts must be used with the appropriate housings
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Prices are net prices without VAT and surcharges. Sale to business customers only.
  • To connect stranded conductors, use a end sleeve.