ÖLFLEX® TRAIN 345 C 600V

Screened multi-core cable according to EN 50264-3-2 type MM S for high requirements in railway applications

ÖLFLEX® TRAIN 345 C 600V - Control cable screened EN 50264-3-2 MM S 0,6/1kV for high requirements in railways/rolling stock; EN 45545: HL1-HL3, NF F 16-101: C/F0

  • Meets EN 50264-3-2 type MM S and
    EN 45545-2
  • High temperature resistance: -50°C up to 120°C
  • Highly oil- and fuel-resistant

Rail Good chemical resistance Flame-retardant Halogen-free Cold-resistant Mechanical resistance Oil-resistant Interference signals Temperature-resistant UV-resistant

CE

Article number Number of cores and mm² per conductor Outer diameter [mm] Copper index (kg/km) Weight (kg/km) Base Unit Price (base price)
15345061
4 X 1.0 8.2 67.46 124
15345000
2 X 1.5 8.2 57.35 125.3
15345001
3 X 1.5 8.7 73.27 149.1
15345025
3 G 1.5 8.7 73.27 149.1
15345002
4 X 1.5 9.4 90.92 180.3
15345026
4 G 1.5 9.4 90.92 180.3
15345003
2 X 2.5 9.0 80.38 160
15345004
3 X 2.5 9.5 107.46 196.2
15345027
3 G 2.5 9.5 107.46 196.2
15345005
4 X 2.5 10.8 147.08 258.5
15345028
4 G 2.5 10.8 147.08 258.5
15345006
2 X 4.0 10.8 126.68 237.2
15345007
3 X 4.0 11.4 167.66 289.6
15345008
4 X 4.0 12.4 210.89 353.9
15345009
2 X 6.0 11.8 171.91 294.3
15345010
3 X 6.0 12.5 233.52 368.3
15345011
4 X 6.0 14.0 297.39 470.2
15345012
2 X 10.0 14.2 258.83 427.9
15345013
3 X 10.0 15.2 378.94 571.9
15345014
4 X 10.0 16.6 485.83 711.2
15345015
2 X 16.0 16.4 411.94 637.3
15345016
3 X 16.0 17.8 574.29 836.3
15345017
4 X 16.0 19.4 741.03 1,040.4
15345018
2 X 25.0 20.2 608.98 939.8
15345019
3 X 25.0 21.4 861.67 1,219.1
15345020
4 X 25.0 24.1 1,147.27 1,601.3
15345021
2 X 35.0 23.2 852.85 1,286.7
15345022
3 X 35.0 24.6 1,203.78 1,668.2
15345023
2 X 50.0 27.6 1,175.17 1,732.8
15345024
3 X 50.0 29.8 1,710.69 2,336.3
Available from stock
Available soon
Not available

Benefits

  • Copper screening complies with EMC requirements and protects against electromagnetic interference
  • Good chemical resistance
  • Resistant to mechanical influences in harsh environmental conditions
  • Extended temperature range
  • Reduced flame spreading increases the protection against damage to persons and property in the event of a fire

Application range

  • For use in railway vehicles, for fixed installations and applications where limited movement may occur
  • Suitable for connecting lamps, heating equipment, switchgear, terminal boxes and power supply
  • Also applicable within oily environments and areas with increased ambient temperature

Product features

  • Fire behaviour according to EN/IEC:
    - Halogen-free acc. to EN 60754-1
    - No corrosive gases acc. to EN 60754-2
    - No fluorine acc. to EN 60684-2
    - No toxic gases acc. to EN 50305
    - Low smoke density acc. to EN 61034-2
    - Flame-retardant acc. to EN 60332-1-2
    - No flame propagation acc. to
    EN 60332-3-24 / EN 60332-3-25 /
    EN 50305
  • Fire behaviour according to NF:
    - Toxicity of gases acc. to NF X 70-100
    - Low smoke density acc. to NF X 10-702
    - No flame propagation acc. to NF C 32-070,
    Cat. C1 and C2
  • Chemical properties:
    - Oil resistant acc. to EN 50264-3-2
    - Fuel resistant acc. to EN 50264-3-2
    - Acid resistant acc. to EN 50264-3-2
    - Alkali resistant acc. to EN 50264-3-2
    - Ozone resistant acc. to EN 50264-3-2/
    EN 50305)
  • Current rating according to EN 50355, appendix A

Norm references / Approvals

  • EN 50264-3-2 type MM S
  • EN 45545-2 HL1, HL2, HL3
  • NF F 16-101 - Classification: C / F0
    (flame propagation / smoke)

Product Make-up

  • Conductor: Fine-wire strands of tinned copper
  • Insulation: Electron beam cross-linked Polymer compound EI 109
  • Colour of insulation: Black with white numbers
  • Wrapping: Halogen-free plastic foil
  • Screen: Tinned-copper braiding
  • Outer sheath: electron beam cross-linked polymer-compound EM 104
  • Outer sheath colour: Black

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000104
  • ETIM 5.0 Class-Description: Control cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000104
  • ETIM 6.0 Class-Description: Control cable

Core identification code

  • Black with white numbers

Conductor stranding

  • Fine-wired/ Finely stranded according to IEC 60228, conductor class 5

Minimum bending radius

  • Fixed installation:
    ≤ 12 mm: 3 x OD
    > 12 mm: 4 x OD
  • Occasional flexing:
    ≤ 12 mm: 4 x OD
    > 12 mm ≤ 20 mm: 5 x OD
    > 20 mm: 6 x OD
    (OD = outer diameter)

Nominal voltage

  • U0/U AC 0.6/1 kV
  • Um AC 1.2 kV
    V0 DC 0.9 kV

Test voltage

  • 3,5 kV AC; 8,4 kV DC

Protective conductor

  • G = with GN-YE protective conductor
    X = without protective conductor

Temperature range

  • Fixed installation:
    -45°C to +120°C (20.000 h)
    -50°C acc. to GOST 20.57.406-81
  • Occasional flexing:
    -35°C to +90°C
    Short circuit: +200°C (5s)

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.
  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
  • Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Prices are net prices without VAT and surcharges. Sale to business customers only.