e-Shop

ÖLFLEX® SERVO Extended Line according to Siemens 6FX8002 (PUR)

Core Line for light duty power chain applications

  • Classical production and assembly
  • Connector with novel, safe screen connection
  • For the most demanding mechanical requirements

Supplementary automation components from LappMechanical and plant engineeringMechanical resistanceOptimum strain reliefRobustReliabilityConnector with standard housing unitWaterproof

CEFire

Article number Length (m)SIEMENS® assembly designationCopper index kg/1.000 piecesOther dimensionsPUBase Unit

Price (base price)

548000016510.02CA31860Other lengths available1
548000029010.02CH00680Other lengths available1
548000039010.02DC10380Other lengths available1
548000041510.02DC20380Other lengths available1
548000044010.02EQ10860Other lengths available1
548000551510.05CS644490Other lengths available1
Available from stock
In stock in Germany
Not available

Benefits

  • Regional manufactured worldwide available
  • Lapp quality standards

Application range

  • Specifically for machine tool building
  • Designed for power chain use: for travel distances up to 100 m (horizontal)
  • For very high dynamic motion sequences

Product features

  • Extended Line for high mechanical stress in Power chains
  • Proven for hightes dynamic stresses and long distances

Norm references / Approvals

  • Design according to SIEMENS® standard 6FX 8002
  • Flame-retardant according to IEC 60332-1-2, VW-1, FT1

Product Make-up

  • Full range of types
  • brake wire with 1.5mm² wire gauge

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000104
  • ETIM 5.0 Class-Description: Control cable

Core identification code

  • Power cores: black with marking U/L1/C/L+; V/L2; W/L3/D /L-; GN/YE protective conductor
  • Optional designs with
    one pair of control cores: black; white
    Two pairs of control cores: black with white numbers: 5, 6, 7, 8

Conductor stranding

  • Extra-fine wire according to VDE 0295, class 6/IEC 60228 class 6

Minimum bending radius

  • For flexible use:
    7.5 x outer diameter (1.5-16 mm²)
    10 x outer diameter (25-50 mm²)
  • Fixed installation: 4 x outer diameter

Nominal voltage

  • Power cores and control cores:
    IEC U0/U: 600/1000 V
  • UL & CSA: 1000 V

Test voltage

  • Core/Core: 4 kV
  • Core/Screen: 4 kV

Protective conductor

  • G = with GN-YE protective conductor

Temperature range

  • Flexing: -40°C to +90°C
    (UL/CSA: +80°C)
  • Fixed installation: -50°C to +90°C
    (UL/CSA: +80°C)

Alternating bending cycles

  • 10 mio. cycles

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Siemens part designations (6FX5002/5008, 6FX7002/7008, 6FX8002/8008) are registered trademarks of Siemens AG, and are listed for comparison purposes only
  • Other lengths and cable terminations are available upon request.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Prices are net prices without VAT and surcharges. Sale to business customers only.
  • Further Article and length online https://servoconfigurator.lappgroup.com/