e-Shop

H05V2-K

Harmonised, flexible single conductor for protected, fixed installation

Ideally suited to meet the stricter thermal requirements of the new IEC-EN-(NBN NEN) 61439 standard

Temperature range to 90°C

CEHARLLOYDS

Article number Core colourConductor cross-section (mm²)Outer diameter [mm]m/ringCopper index (kg/km)Weight (kg/km)Base Unit

Price (base price)

4515001
green/yellow0.52.51004.89
4515002
green/yellow0.752.71007.211
4515003
green/yellow12.81009.614
4515011
black0.52.51004.89
4515012
black0.752.71007.211
4515013
black12.81009.614
4515021
blue0.52.51004.89
4515022
blue0.752.71007.211
4515023
blue12.81009.614
4515141
dark blue0.52.51004.89
4515142
dark blue0.752.71007.211
4515143
dark blue12.81009.614
4515031
brown0.52.51004.89
4515032
brown0.752.71007.211
4515033
brown12.81009.614
4515111
yellow0.52.51004.89
4515112
yellow0.752.71007.211
4515113
yellow12.81009.614
4515121
green0.52.51004.89
4515122
green0.752.71007.211
4515123
green12.81009.614
4515071
violet0.52.51004.89
4515072
violet0.752.71007.211
4515073
violet12.81009.614
4515081
pink0.52.51004.89
4515082
pink0.752.71007.211
4515083
pink12.81009.614
4515091
orange0.52.51004.89
4515092
orange0.752.71007.211
4515093
orange12.81009.614
4515041
red0.52.51004.89
4515042
red0.752.71007.211
4515043
red12.81009.614
4515051
white0.52.51004.89
4515052
white0.752.71007.211
4515053
white12.81009.614
4515061
grey0.52.51004.89
4515062
grey0.752.71007.211
4515063
grey12.81009.614
4515923
Dark blue/white12.81009.614
Available from stock
In stock in Germany
Not available

Benefits

  • Cables' <HAR>marking also stands for the international endorsement of national certification institutes' testing marks and certificates, e. g. <VDE><HAR>. The <HAR>marking is of special importance in case of goods traffic between European countries.
  • Ideally suited to meet the stricter thermal requirements of the new IEC-EN-(NBN NEN) 61439 standard

Application range

  • Internal wiring of devices
  • Laying in tubes, exposed or buried in plaster, and in closed installation ducts
  • Protected installations in pipes and wiring shafts, as well as in installation and assembly
  • Factory wiring

Product features

  • Flame retardant in acc. to IEC 60332-1-2

Norm references / Approvals

  • EN 50525-2-31

Product Make-up

  • Fine-wired copper conductor of bare copper strands in line with conductor class 5 acc. IEC 60228
  • Core insulation: Fully coloured based on PVC, 90°C, TI3 quality

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000993
  • ETIM 5.0 Class-Description: Single core cable

Conductor stranding

  • Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5

Minimum bending radius

  • 4x outer diameter

Nominal voltage

  • U0/U: 300/500 V

Test voltage

  • 2000 V

Temperature range

  • -10°C to +90°C operating temperature
  • Minimum installation temperature: 5°C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Prices are net prices without VAT and surcharges. Sale to business customers only.