e-Shop

X07V-K with twin colour helix insulation

X07V-K, power and control cable for internal wiring, PVC, 450/750 V, class 5, twin colour helix insulation, flame-retardant, spool

  • CPR: Article number choice under www.lappkabel.com/cpr
  • Twin-colour spiralized PVC

CEEACFire

Article number Core colourConductor cross-section (mm²)Outer diameter [mm]m/spoolCopper index (kg/km)Weight (kg/km)Base Unit

Price (base price)

4522261S
blue/white1.52.8 - 3.415014.422
4522921S
Dark blue/white1.52.8 - 3.415014.422
4522211S
black/red1.52.8 - 3.415014.422
4522231S
blue/black1.52.8 - 3.415014.422
4522251S
blue / red1.52.8 - 3.415014.422
4522291S
brown/white1.52.8 - 3.415014.422
4522311S
yellow/red1.52.8 - 3.415014.422
4522371S
violet/white1.52.8 - 3.415014.422
4522381S
orange/black1.52.8 - 3.415014.422
4522391S
orange/white1.52.8 - 3.415014.422
4522401S
red/black1.52.8 - 3.415014.422
4522421S
red/white1.52.8 - 3.415014.422
4522441S
white/blue1.52.8 - 3.415014.422
4522461S
white/red1.52.8 - 3.415014.422
4522221S
black/white1.52.8 - 3.415014.422
4522321S
yellow/white1.52.8 - 3.415014.422
4522262S
blue/white2.53.4 - 4.11002437
4522922S
Dark blue/white2.53.4 - 4.11002437
4522252S
blue / red2.53.4 - 4.11002437
4522292S
brown/white2.53.4 - 4.11002437
4522392S
orange/white2.53.4 - 4.11002437
4522422S
red/white2.53.4 - 4.11002437
4522222S
black/white2.53.4 - 4.11002437
Available from stock
In stock in Germany
Not available

Application range

  • Laying in tubes, exposed or buried in plaster, and in closed installation ducts
  • For direct laying on racks, troughs and tubes only as potential equalisation conductor

Product features

  • Flame-retardant according IEC 60332-1-2
  • Spool: d1 = 18 mm; d2 = 200 mm; b = 85 mm

Norm references / Approvals

  • Based on EN 50525-2-31

Product Make-up

  • Fine-wired copper conductor of bare copper strands in line with conductor class 5 acc. IEC 60228
  • Core insulation: Based on PVC
  • Labelled with coloured stripes

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000993
  • ETIM 5.0 Class-Description: Single core cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000993
  • ETIM 6.0 Class-Description: Single core cable

Conductor stranding

  • Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5

Minimum bending radius

  • 4 x outer diameter if used as defined for H07V-K; 2 x outer diameter for short-term bending

Nominal voltage

  • U0/U: 450/750 V

Test voltage

  • 2500 V

Current rating

  • VDE 0298 Part 4
  • EN 50565-1/ VDE 0298-565-1

Temperature range

  • Fixed installation: -40°C to +70°C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.
  • * Trade product, no Lapp product
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Prices are net prices without VAT and surcharges. Sale to business customers only.