e-Shop

ÖLFLEX® 127 HSLH

Halogen-free control cable, flexible and inexpensive, with CPR Cca, for building wiring

ÖLFLEX® 127 HSLH - halogen-free control cable, HFFR, flexible for various applications, U0/U: 300/500V, CPR Cca classified

  • Cca classified according to CPR
  • For use within public buildings and industrial plants
  • CPR: Article number choice under www.lappkabel.com/cpr

Flame-retardantHalogen-free

CE

Article number Number of cores and mm² per conductorOuter diameter [mm]Copper index (kg/km)Weight (kg/km)Base Unit

Price (base price)

1127408
2 X 0.755.514.443
1127409
3 G 0.755.821.653
1127413
5 G 0.756.93680
1127415
7 G 0.757.550.4101
1127417
12 G 0.7510.186.4181
1127418
18 G 0.7512.0129.6263
1127420
2 X 1.05.819.251
1127421
3 G 1.06.128.863
1127423
4 G 1.06.638.478
1127425
5 G 1.07.34896
1127426
7 G 1.08.167.2126
1127427
12 G 1.010.7115.2220
1127428
18 G 1.012.9172.8325
1127429
2 X 1.56.428.867
1127430
3 G 1.56.843.285
1127432
4 G 1.57.457.6106
1127433
5 G 1.58.372134
1127434
7 G 1.59.0100.8172
1127435
12 G 1.512.2172.8307
1127436
3 G 2.58.372133
1127437
4 G 2.59.096167
1127438
5 G 2.510.1120210
1127440
4 G 4.010.8153.6254
1127441
5 G 4.012.1192318
1127442
4 G 6.013.0230.4375
1127443
5 G 6.014.5288468
1127445
5 G 10.018.1480757
1127447
5 G 16.021.27681112
1127449
5 G 25.026.412001711
Available from stock
In stock in Germany
Not available

Benefits

  • Easy handling and installation due to flexible design
  • Halogen-free and highly flame-retardant materials reduce the risk of fire propagation, high smoke density and toxic fumes in case of fire
  • Classified fire behavior according to EU Directive 305/2011 (CPR) with article number selection under www.lappkabel.com/cpr
  • High electrical performance due to 4 kV test voltage

Application range

  • Public buildings like airports or railway stations
  • Plant engineering, Industrial machinery
    Heating and air-conditioning systems
    Stage applications
  • Intended for use under the European Construction Product Regulation (CPR), refer to catalogue appendix T14
  • Particularly where human and animal life as well as valuable property are exposed to high risk of fire hazards

Product features

  • Flame-retardant according to IEC 60332-1-2
    (flame spread on a single cable)
  • No flame-propagation according to IEC 60332-3-22 and IEC 60332-3-24 respectively IEC 60332-3-25 (Flame spread on vertical cable or wire bundle)
  • Halogen-free according to IEC 60754-1
    (amount of halogen acid gas)
    Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity)
  • Low smoke density according to IEC 61034-2
  • Toxicity according to NES 713-3 and EN 50306-1

Norm references / Approvals

  • Based on EN 50525-3-11
  • Based on EN 50525-2-51

Product Make-up

  • Fine-wire strand made of bare copper wires
  • Core insulation: Halogen-free
  • Cores twisted in layers
  • Outer sheath: Special halogen-free compound, grey (similar to RAL 7001)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000104
  • ETIM 5.0 Class-Description: Control cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000104
  • ETIM 6.0 Class-Description: Control cable

Core identification code

  • Black with white numbers acc. to VDE 0293-334

Conductor stranding

  • Fine wire according to VDE 0295,
    class 5/IEC 60228 class 5

Minimum bending radius

  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 4 x outer diameter

Nominal voltage

  • U0/U: 300/500 V

Test voltage

  • 4000 V

Protective conductor

  • G = with GN-YE protective conductor
  • X = without protective conductor

Temperature range

  • Occasional flexing: -5°C to +70°C
  • Fixed installation: -40°C to +80°C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.
  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
  • Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Prices are net prices without VAT and surcharges. Sale to business customers only.